Previous | Table of Contents | Next |
CONNER CFS1081A, CFS1621A
Interface: | EIDE |
Size: | 3.5 in. third height |
View: | Bottom |
DRIVE SELECT | ||
---|---|---|
Setting | CD | CS |
![]() |
closed | open |
Master drive in a two drive system | closed | open |
Slave drive in a two drive system | open | open |
Cable Select is used to determine master/slave | open | closed |
Note: All other jumpers are factory configured - do not alter. |
CONNER CP30540, CP31370
Interface: | SCSI |
Size: | 3.5 in. third height |
View: | Bottom |
DRIVE SELECTION | |||
---|---|---|---|
Drive Number | Jumper E1 | Jumper E2 | Jumper E3 |
0 | open | open | open |
1 | closed | open | open |
2 | open | closed | open |
3 | closed | closed | open |
4 | open | open | closed |
5 | closed | open | closed |
6 | open | closed | closed |
7 | closed | closed | closed |
CONNECTIONS | |
---|---|
Function | Location |
External Spindle Sync | J3/jumper 1 |
Hard drive active LED | J3/jumper 2 |
Serial I/O connector (for factory use) | J3/jumper 3 - 7 |
USER CONFIGURABLE SETTINGS | ||
---|---|---|
Function | Location | Setting |
![]() |
Jumper E4 | Open |
Spindle motor starts on command only | Jumper E4 | Closed |
![]() |
Jumper E5 | Closed |
Drive Termination disabled | Jumper E5 | Open |
![]() |
Jumper E6 | Closed |
TERMPWR not present | Jumper E6 | Open |
MISCELLANEOUS TECHNICAL NOTES |
---|
a) OE1, OE2, OE3, OE5, and OE6 perform the same
function as and are mutually exclusive with E1, E2, E3, E5, and E6. b) For model CP30540, on PCBA revisions greater than 09230-003 Y1, OE6 is the LED output signal. For model CP31370, on PCBA revisions greater than 09370-002 Y1, OE6 is the LED output signal. c) SCSI parity is always enabled in both directions. |
FUJITSU M2691EQ/ER, M2692EQ/ER, M2693EQ/ER, M2694EQ/ER
Interface: | SCSI |
Size: | 3.5 in. half height |
View: | Bottom |
DRIVE SELECTION - CNH11 | ||||
---|---|---|---|---|
SCSI ID Number | Jumper 1 | Jumper 2 | Jumper 3 | Jumper 4 |
![]() |
open | open | open | open |
1 | closed | open | open | open |
2 | open | closed | open | open |
3 | closed | closed | open | open |
4 | open | open | closed | open |
5 | closed | open | closed | open |
6 | open | closed | closed | open |
7 | closed | closed | closed | open |
8 | open | open | open | closed |
9 | closed | open | open | closed |
10 | open | closed | open | closed |
11 | closed | closed | open | closed |
12 | open | open | closed | closed |
13 | closed | open | closed | closed |
14 | open | closed | closed | closed |
15 | closed | closed | closed | closed |
USER CONFIGURABLE SETTINGS | ||
---|---|---|
Function | Location | Setting |
![]() |
CNH2/jumper 1 | open |
![]() |
CNH2/jumper 2 | open |
![]() |
CNH5 | all open |
![]() |
CNH10/jumper 1 | N/A |
![]() |
CNH10/jumper 2 | closed |
TERMPWR supplied by SCSI pin 26 (ER models only) | CNH10/jumper 2 | open |
![]() |
CNH10/jumper 3 | closed |
TERMPWR is not tied to SCSI pin 26 and terminators | CNH10/jumper 3 | open |
![]() |
CNH10/jumper 4 | closed |
Drive terminators disabled (ER models only) | CNH10/jumper 4 | open |
![]() |
CNH11/jumper 5 | closed |
Write protect enabled | CNH11/jumper 5 | open |
![]() |
SW1/1 | off |
SCSI mode enabled | SW1/1 | on |
![]() |
SW1/2 | off |
Offline diagnostics disabled | SW1/2 | on |
USER CONFIGURABLE SETTINGS (CONTINUED) | ||
---|---|---|
Function | Location | Setting |
![]() |
SW1/3 | on |
UNIT ATTENTION report mode disabled | SW1/3 | off |
![]() |
SW1/4 | on |
Retries are limited to 10 | SW1/4 | off |
![]() |
SW1/5 | on |
SCSI parity check disabled | SW1/5 | off |
![]() |
SW1/6 | on |
Synch/Wide mode transfer requestsdisabled | SW1/6 | off |
![]() |
SW1/7 | on |
LED configured to light when ready | SW1/7 | off |
TERMINATING POWER CONFIGURATION (M269×EQ MODELS ONLY) - CNH10 | ||
---|---|---|
Function | Jumper 2 | Jumper 3 |
![]() |
closed | closed |
TERMPWR connected to drive terminators | closed | open |
TERMPWR connected to SCSI pin 26 and terminators | open | closed |
SPINDLE MOTOR CONFIGURATION | ||
---|---|---|
Setting | CNH11/Jumper 6 | SW1/8 |
![]() |
closed | on |
Spindle motor starts on command only | open | off |
Note: Setting CNH11/jumper 6 to "open" will inhibit user settings. |
CONNECTIONS | |
---|---|
Purpose | Location |
External operator panel connector | CN1 |
External operator panel connector | CN5 |
Spindle synch connector | CN7 |
Previous | Table of Contents | Next |