Previous Table of Contents Next

 

CONNER CFS1081A, CFS1621A

Interface: EIDE
Size: 3.5 in. third height
View: Bottom

DRIVE SELECT
Setting CD CS
Single drive in a system closed open
     Master drive in a two drive system closed open
     Slave drive in a two drive system open open
     Cable Select is used to determine master/slave open closed
     Note: All other jumpers are factory configured - do not alter.

 

CONNER CP30540, CP31370

Interface: SCSI
Size: 3.5 in. third height
View: Bottom

DRIVE SELECTION
Drive Number Jumper E1 Jumper E2 Jumper E3
0 open open open
1 closed open open
2 open closed open
3 closed closed open
4 open open closed
5 closed open closed
6 open closed closed
7 closed closed closed

 
CONNECTIONS
Function Location
External Spindle Sync J3/jumper 1
Hard drive active LED J3/jumper 2
Serial I/O connector (for factory use) J3/jumper 3 - 7

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Spindle motor starts on power-up Jumper E4 Open
     Spindle motor starts on command only Jumper E4 Closed
Drive Termination enabled Jumper E5 Closed
     Drive Termination disabled Jumper E5 Open
TERMPWR supplied by drive to SCSI Interface pin 26 Jumper E6 Closed
     TERMPWR not present Jumper E6 Open

 
MISCELLANEOUS TECHNICAL NOTES
a)  OE1, OE2, OE3, OE5, and OE6 perform the same function as and are mutually exclusive with E1, E2, E3, E5, and E6.
b)  For model CP30540, on PCBA revisions greater than 09230-003 Y1, OE6 is the LED output signal.
For model CP31370, on PCBA revisions greater than 09370-002 Y1, OE6 is the LED output signal.
c)  SCSI parity is always enabled in both directions.

 

FUJITSU CORPORATION

FUJITSU M2691EQ/ER, M2692EQ/ER, M2693EQ/ER, M2694EQ/ER

Interface: SCSI
Size: 3.5 in. half height
View: Bottom

DRIVE SELECTION - CNH11
SCSI ID Number Jumper 1 Jumper 2 Jumper 3 Jumper 4
0 open open open open
     1 closed open open open
     2 open closed open open
     3 closed closed open open
     4 open open closed open
     5 closed open closed open
     6 open closed closed open
     7 closed closed closed open
     8 open open open closed
     9 closed open open closed
     10 open closed open closed
     11 closed closed open closed
     12 open open closed closed
     13 closed open closed closed
     14 open closed closed closed
     15 closed closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Factory configured - do not alter CNH2/jumper 1 open
Factory configured - do not alter CNH2/jumper 2 open
Factory configured - do not alter CNH5 all open
Factory configured - do not alter CNH10/jumper 1 N/A
TERMPWR supplied by drive (ER models only) CNH10/jumper 2 closed
     TERMPWR supplied by SCSI pin 26 (ER models only) CNH10/jumper 2 open
TERMPWR is tied to SCSI pin 26 and terminators CNH10/jumper 3 closed
     TERMPWR is not tied to SCSI pin 26 and terminators CNH10/jumper 3 open
Drive terminators enabled (ER models only) CNH10/jumper 4 closed
     Drive terminators disabled (ER models only) CNH10/jumper 4 open
Write protect disabled CNH11/jumper 5 closed
     Write protect enabled CNH11/jumper 5 open
SCSI-2 mode enabled SW1/1 off
     SCSI mode enabled SW1/1 on
Offline diagnostics enabled SW1/2 off
     Offline diagnostics disabled SW1/2 on

 
USER CONFIGURABLE SETTINGS (CONTINUED)
Function Location Setting
UNIT ATTENTION report mode enabled SW1/3 on
     UNIT ATTENTION report mode disabled SW1/3 off
Retries are unlimited SW1/4 on
     Retries are limited to 10 SW1/4 off
SCSI parity check enabled SW1/5 on
     SCSI parity check disabled SW1/5 off
Synch/Wide mode transfer requests enabled SW1/6 on
     Synch/Wide mode transfer requestsdisabled SW1/6 off
LED configured to light during activity SW1/7 on
     LED configured to light when ready SW1/7 off

 
TERMINATING POWER CONFIGURATION (M269×EQ MODELS ONLY) - CNH10
Function Jumper 2 Jumper 3
TERMPWR connected to SCSI pin 26 and drive terminators closed closed
     TERMPWR connected to drive terminators closed open
     TERMPWR connected to SCSI pin 26 and terminators open closed

 
SPINDLE MOTOR CONFIGURATION
Setting CNH11/Jumper 6 SW1/8
Spindle motor starts on power-up closed on
     Spindle motor starts on command only open off
Note: Setting CNH11/jumper 6 to "open" will inhibit user settings.

 
CONNECTIONS
Purpose Location
External operator panel connector CN1
External operator panel connector CN5
Spindle synch connector CN7

 
Previous Table of Contents Next