Previous Table of Contents Next

 

MAXTOR 81280A2, 81620A3, 81081A2, 82560A4, 82580A5, 82100A4, 83840A6, 83201A6, 84000A6, 84320A8, 85120A8

Device Type Hard Drive
Interface EIDE
Size 3.5 in. third height
View Bottom

DRIVE CONFIGURATION
Setting J48 J50
Drive is master open closed
     Drive is slave open open
     Cable Select closed open

 
USER CONFIGURABLE SETTINGS
Function Label Position
Factory configured - do not alter. J42 unidentified
Factory configured - do not alter. J44 unidentified
     4092 Cylinder limitation disabled J46 open
     4092 Cylinder limitation enabled J46 closed
Note: If system hangs during boot, before accessing BIOS, or during boot after BIOS SETUP has been run, close jumper J46 and run "Max-Blast" software to complete hard drive installation.

 

MAXTOR MX9217SSW

Interface: SCA SCSI-2 wide
Size: 3.5 in. third height
View: Bottom

CONNECTIONS
Purpose Location
LED J2/jumper 4
Spindle sync J2/jumper 7

 
DRIVE CONFIGURATION
SCSI Address J2/Jumper 9 J2/Jumper 10 J2/Jumper 11 J2/Jumper 12
0 open open open open
1 open open open closed
2 open open closed open
3 open open closed closed
4 open closed open open
5 open closed open closed
6 open closed closed open
7 open closed closed closed
8 closed open open open
9 closed open open closed
10 closed open closed open
11 closed open closed closed
12 closed closed open open
13 closed closed open closed
14 closed closed closed open
15 closed closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Write protect disabled J2/jumper 1 open
     Write protect enabled J2/jumper 1 closed
SCSI mode is SCSI-2 (if SCSI 1/2 pin is active) J2/pins 1 & 3 open
     SCSI mode is SCSI-1 (if SCSI 1/2 pin is active) J2/pins 1 & 3 closed
     SDTR message disabled (if SDTR function is active) J2/jumper 3 open
     SDTR message enabled (if SDTR function is active) J2/jumper 3 closed
     Unit attention enabled (if U/A function is active) J2/jumper 3 open
     Unit attention disabled (if U/A function is active) J2/jumper 3 closed
     Spindle motor starts on power-up J2/jumper 5 open
     Spindle motor starts on command only J2/jumper 5 closed
     Termination enabled J4/jumper 1 closed
     Termination disabled J4/jumper 1 open
Factory configured - do not alter J4/jumper 2 unidentified
Factory configured - do not alter J4/jumper 3 unidentified

 
MISCELLANEOUS TECHNICAL NOTES
On models with SCA connector only passive termination is available.

 
Previous Table of Contents Next