QUANTUM VP31110W/WD, VP32210W/WD (CAPELLA WIDE SCSI SERIES)

Interface: SCSI-2 F/W/D
Size: 3.5 in. third height
View: Bottom

USER CONFIGURABLE SETTINGS
Function Location Setting
Active termination enabled J2/jumper 5 closed
Active termination disabled J2/jumper 5 open
Spindle motor starts on power-up J3/jumper 1 closed
Spindle motor starts on command only J3/jumper 1 open
TRMPWR supplied to SCSI bus J4 closed
TRMPWR is not supplied to SCSI bus J4 open
Drive is first or last drive in chain terminators installed
Drive is not first or last drive in chain terminators removed

 
DRIVE SELECTION - J2
Drive ID Jumper 1 Jumper 2 Jumper 3 Jumper 4
0 open open open open
1 closed open open open
2 open closed open open
3 closed closed open open
4 open open closed open
5 closed open closed open
6 open closed closed open
7 closed closed closed open
8 open open open closed
9 closed open open closed
10 open closed open closed
11 closed closed open closed
12 open open closed closed
13 closed open closed closed
14 open closed closed closed
15 closed closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location
Remote Busy LED J3/pins 11 & 13
Remote Fault LED J3/pins 13 & 14

 
MISCELLANEOUS TECHNICAL NOTES
a)  The wide differential drives ("WD" models) do not provide active termination.
b)  Busy LED & fault LED can also be connected in J2 jumper block.
c)  All other jumpers and their function are unidentified.

 

QUANTUM ATLAS XP SERIES: XP31070S, XP32150S, XP34300S

QUANTUM ATLAS II SERIES: XP32181S, XP34361S, XP39100S

Interface: SCSI-2 Fast (ATLAS XP)
SCSI-3 (ATLAS II)
Size: 3.5 in. half height
View: Bottom

DRIVE SELECTION - J3
Drive ID Jumper 1 Jumper 2 Jumper 3
0 open open open
1 closed open open
2 open closed open
3 closed closed open
4 open open closed
5 closed open closed
6 open closed closed
7 closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Active termination enabled J4 closed
Active termination disabled J4 open
TRMPWR supplied to SCSI bus J5 closed
TRMPWR is not supplied to SCSI bus J5 open
Spindle motor starts on power-up with delay of SCSI ID x 12 sec. J3/jumper 7 closed
Spindle motor starts on command only J3/jumper 7 open
Write protect enabled J3/jumper 9 closed
Write protect disabled J3/jumper 9 open
Note: jumpers not mentioned in this document are unidentified.

 
CONNECTIONS
Function Location
Spindle sync J3/pins 10 & 19
Remote busy LED J3/pins 11 & 9
Remote fault LED J3/pins 11 & 7

 
Previous Table of Contents Next