Previous Table of Contents Next

 

SEAGATE ST15230NC

Interface: SCSI-2 Fast
Size: 3.5 in. half height
View: Bottom

DRIVE SELECTION - J6
SCSI ID Number Jumper 1 Jumper 2 Jumper 3
0 open open open
     1 closed open open
     2 open closed open
     3 closed closed open
     4 open open closed
     5 closed open closed
     6 open closed closed
     7 closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Factory configured - do not alter J2/jumper 1 open
Factory configured - do not alter J2/jumper 2 open
Factory configured - do not alter J2/jumper 3 open
SCSI parity enabled J2/jumper 4 closed
     SCSI parity disabled J2/jumper 4 open
Write protect disabled J2/jumper 5 open
     Write protect enabled J2/jumper 5 closed
Factory configured - do not alter J2/jumper 8 open
Factory configured - do not alter J6/jumper 5 open
Factory configured - do not alter J6/jumper 6 open

 
SPINDLE MOTOR OPTIONS - J2
Function Jumper 6 Jumper 7
Spindle motor starts on power up open open
     Spindle motor starts on command only closed open
     Spindle motor delay enabled (SCSI ID x 12 sec.) open closed
     Spindle motor delay disabled closed closed

 
CONNECTIONS
Function Location
Remote LED connection J6/jumper 4

 
MISCELLANEOUS TECHNICAL NOTES
a)  J6/jumpers 7-10 come with cover installed - do not remove.
b)  SCSI ID, spindle motor options, sync. connector, remote LED are included in the 80 pin interface.
c)  Do not use both the 80 pin connector and J2 or J6 for the same function.

 

SEAGATE HAWK 2LP (VER. 2), HAWK 4 (VER. 1), ST15230W/WD, ST31230W/WD, ST32430W/WD

Interface: SCSI-2 Fast Wide
Size: 3.5 in. third height
View: Bottom

DRIVE SELECTION - J1
SCSI ID Number Jumper 1 Jumper 2 Jumper 3 Jumper 4
0 open open open open
1 closed open open open
2 open closed open open
3 closed closed open open
4 open open closed open
5 closed open closed open
6 open closed closed open
7 closed closed closed open
8 open open open closed
9 closed open open closed
10 open closed open closed
11 closed closed open closed
12 open open closed closed
13 closed open closed closed
14 open closed closed closed
15 closed closed closed closed

 
USER CONFIGURABLE SETTINGS
Function Location Setting
Factory configured - do not alter J1/jumper 5 open
Factory configured - do not alter J1/jumper 6 open
Factory configured - do not alter J2/jumper 3 open
SCSI parity check enabled J2/jumper 4 closed
     SCSI parity check disabled J2/jumper 4 open
Write protect disabled J2/jumper 5 open
     Write protect enabled J2/jumper 5 closed
Terminating resistors enabled ("W" models only) J2/jumper 8 closed
     Terminating resistors disabled ("W" models only) J2/jumper 8 open
Factory configured - do not alter ("WD" models only) J2/jumper 8 N/A

 
SPINDLE MOTOR OPTIONS - J2
Function Jumper 6 Jumper 7
Spindle motor starts on power up open open
     Spindle motor starts on command only closed open
     Spindle motor delay enabled (SCSI ID x 12 sec.) open closed
     Spindle motor delay disabled closed closed

 
TERMINATION POWER - J2
Setting Jumper 1 Jumper 2
TERMPWR supplied by drive to drive open closed
     TERMPWR supplied by drive to SCSI pin 26 closed open
     TERMPWR supplied by drive to drive and to SCSI pin 26 closed closed
     TERMPWR not connected to drive or SCSI pin 26 open open
     TERMPWR supplied by SCSI bus pin 26 to drive ("W" models only) pins 2 & 4 closed
Note: For 15230W/WD the SCSI bus TERMPWR pins are 17, 18, 51 & 52.

 
CONNECTIONS
Function Location
Remote LED connection J1/pins 8 & 11

 
MISCELLANEOUS TECHNICAL NOTES
a)  J1 & J6 are mutually exclusive.
When configuring the drive with J1, do not alter J6. Same settings and pin-out apply for both jumpers.
b)  J6 jumpers 7-10 are shipped with cover installed.
c)  Do not remove cover or install jumpers 11.

 
Previous Table of Contents Next